  Overview
  At Solarbotics, we've been getting quite a few questions regarding the "real-world" performance of our solarcells. Although we do have the official Panasonic Sunceram datasheets, it is written in a quite technical manner and does not include practical design data. With that in mind, we have generated the following - the first of three sets of data for use by the BEAM community. This first set of data is taken with direct-sunlight performance in mind. The second and third sets will be measured under halogen and incandescent lighting (stay tuned...).
  Data Acquisition Procedure
  Solarcell voltage across resistance values recorded on June 20 between 13:07 and 13:25. Solarcell capacitor charging values for capacitors between 1000uF and 4700uF recorded on June 22 Between 13:30 and 14:00.Solarcell capacitor charging values for capacitors between .047F and 1.0F recorded on June 25 between 13:25 and 14:10.Summer solstice on June 21, maximum sunlight at 13:37 (located in Calgary, Alberta, Canada).Testing apparatus consists of a basic stamp 2 for data logging and a ADC0831 chip for analog to digital conversion, 8 bit accuracy (0.02 volt resolution). When testing multiple resistive loads, relays were used to switch the load across the solarcell with a 200ms settle time. The basic stamp controlled sequencing and data logging by measuring the voltage across each switched load.When testing the charge rate of multiple capacitors, the capacitor was shorted by a relay for a period of five seconds, then released to charge by the solarcell. Voltage readings were taken between .2 and 5 seconds, depending on estimated total charge time. An 80% open voltage line is also indicated on the graphs.
 
  Charge Times sorted by Solar Cell
 
  • SC2422 charging CP.33F, 2xCP.33F in series, CP1F and 2xCP1F in series (GIF)

  • SC2433 charging CP.33F, 2xCP.33F in series, CP1F and CP1F in series (GIF)

  • SC3733 charging CP.33F, 2xCP.33F in series, CP1F and CP1F in series (GIF)

  • SC3766 charging CP1000uF, CP3300uF (actual and estimate), CP4700uF (actual and estimate) (GIF)

  • 10xSCPD charging CP1000uF, CP3300uF (actual and estimate), CP4700uF (actual and estimate) (GIF)

  • 10xSCPD charging CP.047F Tokin capacitor (GIF)

 
  Charge Times sorted by Capacitor
 
  • CP.33F charged by SC2422, SC2433 and SC3733 (GIF)

  • 2xCP.33F in series charged by SC2422, SC2433 and SC3733 (GIF)

  • CP1F charged by SC2422, SC2433 and SC3733 (GIF)

  • 2xCP1F charged by SC2422, SC2433 and SC3733 (GIF)

 
  Solar Cell output under Resistance
 
  • Voltage vs Resistance for SC2422, SC2433, SC3733, SC3766 and SCPDx10 (GIF)

  • Current vs Resistance for SC2422, SC2433, SC3733, SC3766 and SCPDx10 (GIF)

  • Power vs Resistance for SC2422, SC2433, SC3733, SC3766 and SCPDx10 (GIF)

 
  Complete Data Sheet Download
  For those of you who would rather have access to the complete data sheets and charts for the 2001 Solar Cell Analysis, we provide this information in the Microsoft Excel format.Solarcell Data Sheet A - 88KB
Solarcell Data Sheet B - 388KB
 
  Disclaimer:  
  Although the information is provided freely, we request that any reproduction or reference to the above data be included with proper accreditation to Solarbotics Ltd. Additionally, although we have performed these tests in good faith, we do not and cannot warrantee this data in any way.

MORE POSTS

October 20, 2011
The Many Faces of SAFE

The SAFE (Solarbotics Arduino Freeduino Enclosure) is a marvelous contraption of laser-cut acrylic that makes a complete enclosure for your Arduino project. It gives you a protective shell with enough room for a basic shield, with knock-outs for power and USB connection. It even has a power switch. The big problem with Arduinos and Freeduinos, […]

June 5, 2012
Russian ARDX Documentation

Примечание переводчика: первый раз перевел - не поняли, второй раз перевел - не поняли, третий раз перевел - аж сам понял! (что электроника это круто), а они все нет... If you can't read the above sentence, don't worry - you can rest assured that your browser has not all of the sudden switched to Russian-o-vision. […]

July 12, 2007
BEP Application: Wilf Rigter Solar Power...

The following instructions detail how to build a Solar Power Smart Head version 3. The Head will seek light and when it finds the brightest source it will go into a low current standby mode. This version also comes with an low power FLED circuit to indicate when the head is active.

December 20, 2004
ScoutWalker III back in stock!

There's still time to get your Solarbotics order in time for Christmas if you select courier shipping (maybe even just airmail, if you get the order in today and you live closeby). We now have a solid inventory of ScoutWalker III kits in stock, so if you want to have one from "Santa" this year, […]

1 93 94 95 96 97 253
Solarbotics Ltd Logo
Solarbotics has been operating for more than 25 years, bringing electronics know-how and supplies to both the electronics professional and hobbyist. We'll be happy to help you too!

Solarbotics, Ltd. is not responsible for misprints or errors on product prices or information. For more information, please see our Terms and Conditions.

Warning: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
Please visit www.P65Warnings.ca.gov for more information. This item was manufactured prior to August 31, 2018.

cart