Parallax is already sold out of the successor to the Scribbler. We have some still!
Overview | ||
At Solarbotics, we've been getting quite a few questions regarding the "real-world" performance of our solarcells. Although we do have the official Panasonic Sunceram datasheets, it is written in a quite technical manner and does not include practical design data. With that in mind, we have generated the following - the first of three sets of data for use by the BEAM community. This first set of data is taken with direct-sunlight performance in mind. The second and third sets will be measured under halogen and incandescent lighting (stay tuned...). | ||
Data Acquisition Procedure | ||
Solarcell voltage across resistance values recorded on June 20 between 13:07 and 13:25. Solarcell capacitor charging values for capacitors between 1000uF and 4700uF recorded on June 22 Between 13:30 and 14:00.Solarcell capacitor charging values for capacitors between .047F and 1.0F recorded on June 25 between 13:25 and 14:10.Summer solstice on June 21, maximum sunlight at 13:37 (located in Calgary, Alberta, Canada).Testing apparatus consists of a basic stamp 2 for data logging and a ADC0831 chip for analog to digital conversion, 8 bit accuracy (0.02 volt resolution). When testing multiple resistive loads, relays were used to switch the load across the solarcell with a 200ms settle time. The basic stamp controlled sequencing and data logging by measuring the voltage across each switched load.When testing the charge rate of multiple capacitors, the capacitor was shorted by a relay for a period of five seconds, then released to charge by the solarcell. Voltage readings were taken between .2 and 5 seconds, depending on estimated total charge time. An 80% open voltage line is also indicated on the graphs. |
||
Charge Times sorted by Solar Cell | ||
|
||
Charge Times sorted by Capacitor | ||
Solar Cell output under Resistance | ||
Complete Data Sheet Download | ||
For those of you who would rather have access to the complete data sheets and charts for the 2001 Solar Cell Analysis, we provide this information in the Microsoft Excel format.Solarcell Data Sheet A - 88KB Solarcell Data Sheet B - 388KB |
||
Disclaimer: | ||
Although the information is provided freely, we request that any reproduction or reference to the above data be included with proper accreditation to Solarbotics Ltd. Additionally, although we have performed these tests in good faith, we do not and cannot warrantee this data in any way. |
Parallax is already sold out of the successor to the Scribbler. We have some still!
Remember that time we said we were going to close for vacation, but our website and phones would stay on duty to take your messages? Well, it looks like the phones are revolting, and demanding time off immediately. Right now we're having issues with our office system, and we're unable to take calls. Please shoot […]
Solarbotics will be slightly altering our holiday hours to enable staff to spend time with friends & family. We will be closed Friday, December 24th to Tuesday, December 28th and Friday, December the 31st. On Monday, January 3rd, 2005 we will resume our normal hours, 9:00am - 6:00pm MST. Solarbotics wishes all the best to […]
Another year has snuck by, and here we are on the cusp of another winter holiday season! If you want to give a Solarbotics Kit (and we hope you do...) to somebody special this year, you should be aware of our shipping deadlines. It's not recommended to use ground shipping now (which can take up […]
Solarbotics, Ltd. is not responsible for misprints or errors on product prices or information. For more information, please see our Terms and Conditions.
Warning: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
Please visit www.P65Warnings.ca.gov for more information. This item was manufactured prior to August 31, 2018.