Overview | ||
At Solarbotics, we've been getting quite a few questions regarding the "real-world" performance of our solarcells. Although we do have the official Panasonic Sunceram datasheets, it is written in a quite technical manner and does not include practical design data. With that in mind, we have generated the following - the first of three sets of data for use by the BEAM community. This first set of data is taken with direct-sunlight performance in mind. The second and third sets will be measured under halogen and incandescent lighting (stay tuned...). | ||
Data Acquisition Procedure | ||
Solarcell voltage across resistance values recorded on June 20 between 13:07 and 13:25. Solarcell capacitor charging values for capacitors between 1000uF and 4700uF recorded on June 22 Between 13:30 and 14:00.Solarcell capacitor charging values for capacitors between .047F and 1.0F recorded on June 25 between 13:25 and 14:10.Summer solstice on June 21, maximum sunlight at 13:37 (located in Calgary, Alberta, Canada).Testing apparatus consists of a basic stamp 2 for data logging and a ADC0831 chip for analog to digital conversion, 8 bit accuracy (0.02 volt resolution). When testing multiple resistive loads, relays were used to switch the load across the solarcell with a 200ms settle time. The basic stamp controlled sequencing and data logging by measuring the voltage across each switched load.When testing the charge rate of multiple capacitors, the capacitor was shorted by a relay for a period of five seconds, then released to charge by the solarcell. Voltage readings were taken between .2 and 5 seconds, depending on estimated total charge time. An 80% open voltage line is also indicated on the graphs. |
||
Charge Times sorted by Solar Cell | ||
|
||
Charge Times sorted by Capacitor | ||
Solar Cell output under Resistance | ||
Complete Data Sheet Download | ||
For those of you who would rather have access to the complete data sheets and charts for the 2001 Solar Cell Analysis, we provide this information in the Microsoft Excel format.Solarcell Data Sheet A - 88KB Solarcell Data Sheet B - 388KB |
||
Disclaimer: | ||
Although the information is provided freely, we request that any reproduction or reference to the above data be included with proper accreditation to Solarbotics Ltd. Additionally, although we have performed these tests in good faith, we do not and cannot warrantee this data in any way. |
Solarbotics will be closing for the winter holidays as of Tuesday, December 24th. We will be open again December 30, 2002.
A brilliant selection of new smart LED strips with various features. They are addressable, white RGB, or full-color RGBW, available on spools or per meter to add blindingly bright effects to your project. Some so bright, we had to shoot them at 1/4 power to avoid freaking out the camera exposure. 5V RGB Addressable Serpentine […]
This is Gareth Branwyn's latest book on robotics. Why should you care? Well, our own Dave Hrynkiw (dat be me) was honoured with the task of tech-editting it. It's a fun read, with some BEAM and not-so-BEAM projects, so if you're a raw newbie to robotics, this belongs on your bookshelf next to "Junkbots, Bugbots […]
Ok, ok - we've been getting requests (no; more like demands) that we offer a bit of a deal for getting the GM15's in pairs. Alright then. How does $30USD or $40Cdn a pair strike you? Ok, now let's see some nano-sumo robots! "Wot's this? A microcontroller at Solarbotics??" Yup. The Atmel ATMega8L is part […]
Solarbotics, Ltd. is not responsible for misprints or errors on product prices or information. For more information, please see our Terms and Conditions.
Warning: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
Please visit www.P65Warnings.ca.gov for more information. This item was manufactured prior to August 31, 2018.